Schematics and connector pinout: Difference between revisions

From openinverter.org wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 20: Line 20:
|DIS_DRV
|DIS_DRV
|3404 (YE) Chg cord plugged in
|3404 (YE) Chg cord plugged in
|
|Charge cable plugged in (12V, Motor PWM inhibit when low)
|-
|-
|4
|4
|USART_TX
|USART_TX
|3017 (DG/WH) SIADIS RXD
|3017 (DG/WH) SIADIS RXD
|
|Serial comm. Or WiFi module
|-
|-
|5
|5
|CAN_H
|CAN_H
|914 (TN/OG) J1850 bus plus
|914 (TN/OG) J1850 bus plus
|
|CAN BUS
|-
|-
|6
|6
|STOP_RLY
|STOP_RLY
|3235 (YE/LG) Stop lamp RLY
|3235 (YE/LG) Stop lamp RLY
|
|Stop signal when regen (Active, GND. Inactive, Z)
|-
|-
|7
|7
|VSS_OUT
|VSS_OUT
|679 (GY/BK) Vehicle speed signal
|679 (GY/BK) Vehicle speed signal
|
|Vehicle Speed Signal, to IAA and Power steering (12v PWM)
|-
|-
|8
|8
|SIG_MAIN_C
|SIG_MAIN_C
|3986 (DG) Main contactor
|3986 (DG) Main contactor
|
|DC contactor and oil pump relay (Active, GND. Inactive, Z)
|-
|-
|9
|9
|12V_ALL_T
|12V_ALL_T
|276 (BN) Power hot all time
|276 (BN) Power hot all time
|
|12V all time (used for relay protection diode)
|-
|-
|10
|10
|12V_RUN_START
|12V_RUN_START
|640 (RD/YE) Power run/start
|640 (RD/YE) Power run/start
|
|12v in RUN, START, ACC
|-
|-
|11
|11
|MTMP+
|MTMP+
|3757 (BK/WH) Motor Temp sensor
|3757 (BK/WH) Motor Temp sensor
|
|Motor Temp sensor Input +
|-
|-
|12
|12
Line 70: Line 70:
|3.3V_USART
|3.3V_USART
|3018 (WH) SIADIS d/l
|3018 (WH) SIADIS d/l
|
|Serial comm. Or WiFi module
|-
|-
|14
|14
|USART_RX
|USART_RX
|3016 (LG/BK) SIADIS TXD
|3016 (LG/BK) SIADIS TXD
|
|Serial comm. Or WiFi module
|-
|-
|15
|15
|CAN_L
|CAN_L
|915 (PK/LB) J1850 bus minus
|915 (PK/LB) J1850 bus minus
|
|CAN BUS
|-
|-
|16
|16
Line 95: Line 95:
|PRECHG_RLY
|PRECHG_RLY
|3991 (TN) Precharge RLY contr
|3991 (TN) Precharge RLY contr
|
|Precharge relay (Active, GND. Inactive, Z)
|-
|-
|19
|19
|12V_ALL_T
|12V_ALL_T
|276 (BN) Power hot all time
|276 (BN) Power hot all time
|
|12V all time (used for relay protection diode)
|-
|-
|20
|20
|12V_RUN_START
|12V_RUN_START
|640 (RD/YE) Power run/start
|640 (RD/YE) Power run/start
|
|12v in RUN, START (this will power up the inverter ECU)
|-
|-
|21
|21
Line 120: Line 120:
|GND_USART
|GND_USART
|3019 (GY/BK) SIADIS GND
|3019 (GY/BK) SIADIS GND
|
|Serial comm. Or WiFi module
|-
|-
|24
|24
Line 135: Line 135:
|SIG_VSS_B
|SIG_VSS_B
|3701 (DB/WH) VSS B signal
|3701 (DB/WH) VSS B signal
|
|Encoder channel B
|-
|-
|27
|27
Line 150: Line 150:
|GND
|GND
|3233 (BK/LB) GND
|3233 (BK/LB) GND
|
|GND
|-
|-
|30
|30
|5V_VSS
|5V_VSS
|3707 (OG) VSS +12 ref
|3707 (OG) VSS +12 ref
|
|Encoder PWR +5V
|-
|-
|31
|31
|CH_GND
|CH_GND
|57 (BK) Chassis GND
|57 (BK) Chassis GND
|
|Chassis GND
|-
|-
|32
|32
Line 180: Line 180:
|EMCY_PWR
|EMCY_PWR
|3997 (DG) Emergency PWR Off
|3997 (DG) Emergency PWR Off
|
|EPO Emergency Power Off (Active, Z. Inactive, 12V)
|-
|-
|36
|36
|SIG_VSS_A
|SIG_VSS_A
|3700 (LB/RD) VSS A signal
|3700 (LB/RD) VSS A signal
|
|Encoder channel A
|-
|-
|37
|37
|OIL_P_RLY
|OIL_P_RLY
|3005 (VT/LG) Oil pump RLY
|3005 (VT/LG) Oil pump RLY
|
|DC contactor and oil pump relay (Active, GND. Inactive, Z)
|-
|-
|38
|38
Line 200: Line 200:
|GND
|GND
|3233 (BK/LB) GND
|3233 (BK/LB) GND
|
|GND
|-
|-
|40
|40
|GND_VSS
|GND_VSS
|3659 (BK/PK) VSS GND
|3659 (BK/PK) VSS GND
|
|Encoder GND
|}
|}

Revision as of 21:54, 23 December 2019

joromy_tim_w_GND_fill_15b - Schematic.pdf

TIM connector C4998
Name (New TIM) Circuit (Old TIM) Function (New TIM)
1 NC NC
2 MTMP- 3708 (BN) Motor Temp sensor Motor Temp sensor Input -
3 DIS_DRV 3404 (YE) Chg cord plugged in Charge cable plugged in (12V, Motor PWM inhibit when low)
4 USART_TX 3017 (DG/WH) SIADIS RXD Serial comm. Or WiFi module
5 CAN_H 914 (TN/OG) J1850 bus plus CAN BUS
6 STOP_RLY 3235 (YE/LG) Stop lamp RLY Stop signal when regen (Active, GND. Inactive, Z)
7 VSS_OUT 679 (GY/BK) Vehicle speed signal Vehicle Speed Signal, to IAA and Power steering (12v PWM)
8 SIG_MAIN_C 3986 (DG) Main contactor DC contactor and oil pump relay (Active, GND. Inactive, Z)
9 12V_ALL_T 276 (BN) Power hot all time 12V all time (used for relay protection diode)
10 12V_RUN_START 640 (RD/YE) Power run/start 12v in RUN, START, ACC
11 MTMP+ 3757 (BK/WH) Motor Temp sensor Motor Temp sensor Input +
12 NC NC
13 3.3V_USART 3018 (WH) SIADIS d/l Serial comm. Or WiFi module
14 USART_RX 3016 (LG/BK) SIADIS TXD Serial comm. Or WiFi module
15 CAN_L 915 (PK/LB) J1850 bus minus CAN BUS
16 NC NC
17 NC NC
18 PRECHG_RLY 3991 (TN) Precharge RLY contr Precharge relay (Active, GND. Inactive, Z)
19 12V_ALL_T 276 (BN) Power hot all time 12V all time (used for relay protection diode)
20 12V_RUN_START 640 (RD/YE) Power run/start 12v in RUN, START (this will power up the inverter ECU)
21 NC NC
22 NC NC
23 GND_USART 3019 (GY/BK) SIADIS GND Serial comm. Or WiFi module
24 NC NC
25 NC NC
26 SIG_VSS_B 3701 (DB/WH) VSS B signal Encoder channel B
27 NC NC
28 NC NC
29 GND 3233 (BK/LB) GND GND
30 5V_VSS 3707 (OG) VSS +12 ref Encoder PWR +5V
31 CH_GND 57 (BK) Chassis GND Chassis GND
32 NC NC
33 NC NC
34 NC NC
35 EMCY_PWR 3997 (DG) Emergency PWR Off EPO Emergency Power Off (Active, Z. Inactive, 12V)
36 SIG_VSS_A 3700 (LB/RD) VSS A signal Encoder channel A
37 OIL_P_RLY 3005 (VT/LG) Oil pump RLY DC contactor and oil pump relay (Active, GND. Inactive, Z)
38 NC NC
39 GND 3233 (BK/LB) GND GND
40 GND_VSS 3659 (BK/PK) VSS GND Encoder GND