Webasto HVH50

From openinverter.org wiki
Jump to navigation Jump to search
Webasto HVH50 water heater

The Webasto HVH series are electrical water heaters typically used in popular PHEV.

Connectors

Webasto HVH50 connectors

The HV connector is a Tyco HVA280 connector with A-key (might be different on other devices).

The small center pins are for interlock (detect that the connector is seated). The right pin (with tab facing upwards) is HV+, the left one HV-

The LV connector is best found by the VW part number 1J0973714

  • Pin 1 is permanent 12V
  • Pin 2 is an analog output
  • Pin 3 is an analog or PWM input
  • Pin 5 and 7 are interlock (probably must be shorted)
  • Pin 6 is LIN
  • Pin 4 and 8 are unused

Ground must be connected to the case via a stud.

Communication & Control

While there is a document describing the LIN interface , Webasto seems to have altered the interface for different OEMs. According to the document, LIN bus speed is 19200 but on a unit obtained from ebay it was 9600. So always try both.

The data format seems common as follows

HVH LIN Protocol
Command Possible IDs Byte 1 2 3 4 5 6 7 8
Write power 35 0=Off, 1=On Temp setpoint

1 digit=1 degree

Offset -40

Power limit

1 digit=40W

- - - - -
Read Status 24 or 23 various status info
Read Meas 40 or 22 Lin status

0=good, 1=issue

Outlet temp

Scaling as above

Inlet temp Unknown Voltage LSB Voltage MSB Power?

1 digit=20W

Unknown

Some units allow control via a simple on off signal on Pin 3 (12V=heat up liquid to 85°C) and some units allow a strange PWM control between 50-100Hz where 25%-81% duty cycles allow setting various power levels.