CAN table CAN STD

From openinverter.org wiki
Revision as of 11:36, 20 February 2020 by Joromy (talk | contribs)
Jump to navigation Jump to search

The Status cell will have several status like:

  • Suggested,
  • Approved, looks good go ahead and put in firmware
  • STD, is established and standard in firmware

Sign with your forum name, please do not delete any rows, just add a new.

Openiverter CAN data out.
Function CAN-Id Byte0 Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Description Status Sign
DIR 0x123 123 123 123 123 123 123 123 123 test joromy
FWD 0x123 123 test joromy
REW 0x123 123 joromy
P/N 0x123 123 joromy
Simp BMS CAN data out.
Function CAN-Id Byte0 Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Description Satus Sign
SOC 0x355 0-100 STD joromy
BMS Boot 0x355 0 Status Suggested joromy
BMS Ready 0x355 1 Status Suggested joromy
BMS Drive 0x355 2 Status Suggested joromy
BMS Charge 0x355 3 Status Suggested joromy
BMS Precharge 0x355 4 Status Suggested joromy
BMS Error 0x355 5 Status Suggested joromy
BMS Heat/cool 0x355 6 Staus Suggested joromy
Pack Volt 0x356 LSB MSB STD joromy
Tot. Amps 0x356 LSB MSB STD joromy
Avg. celltemp 0x356 LSB MSB STD joromy
Lo cellvolt 0x373 LSB MSB Suggested joromy
Hi cellvolt 0x373 LSB MSB Suggested joromy
Lo celltemp 0x373 LSB MSB Suggested joromy
HI celltemp 0x373 LSB MSB Suggested joromy
Tesla charger CAN data out (only DUE based board)
Function CAN-Id Byte0 Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Description Status Sign
Unconnected 0x3D8 0 Suggested joromy
Buttonpress 0x3D8 1 Suggested joromy
Connected 0x3D8 2 Suggested joromy
EVSE disable 0x3D8 0 Normal mode Suggested joromy
EVSE enable 0x3D8 1 AC enable, no charge Suggested joromy