<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://openinverter.org/wiki/index.php?action=history&amp;feed=atom&amp;title=Tesla_SDU_with_Zombieverter</id>
	<title>Tesla SDU with Zombieverter - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://openinverter.org/wiki/index.php?action=history&amp;feed=atom&amp;title=Tesla_SDU_with_Zombieverter"/>
	<link rel="alternate" type="text/html" href="https://openinverter.org/wiki/index.php?title=Tesla_SDU_with_Zombieverter&amp;action=history"/>
	<updated>2026-04-28T16:51:32Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.1</generator>
	<entry>
		<id>https://openinverter.org/wiki/index.php?title=Tesla_SDU_with_Zombieverter&amp;diff=5574&amp;oldid=prev</id>
		<title>Steve16: /* Tesla SDU with Zombieverter */ Note 4 text deleted as no longer applicable with new, simplified wiring diagram.</title>
		<link rel="alternate" type="text/html" href="https://openinverter.org/wiki/index.php?title=Tesla_SDU_with_Zombieverter&amp;diff=5574&amp;oldid=prev"/>
		<updated>2025-02-01T15:28:21Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;Tesla SDU with Zombieverter: &lt;/span&gt; Note 4 text deleted as no longer applicable with new, simplified wiring diagram.&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 15:28, 1 February 2025&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l8&quot;&gt;Line 8:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 8:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#A third device must be on the Can bus with the Zombieverter and Inverter.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#A third device must be on the Can bus with the Zombieverter and Inverter.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#Requirements 1. and 2. are satisfied in the drawing by the IVT shunt.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#Requirements 1. and 2. are satisfied in the drawing by the IVT shunt.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;All devices except the Zombieverter are shown as powered by the ignition switch.  Some devices may need to move to permanent 12V supply to support other functions, such as charging.&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;Text deleted&#039;&#039;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#An inverter power relay is required for Zombieverter control.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#An inverter power relay is required for Zombieverter control.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#Can mapping to pass data and commands from the Zombieverter to the inverter is hard coded in the firmware for both devices.  Manual mapping is required for the inverter to transmit data to the Zombieverter.  The Zombieverter is hard coded to receive this data.  The following values need to be manually mapped in the inverter. Note: mapping uses hex address values, multipliers may need to change to provide correct values (confirm in Zombieverter spot values), inverter udc gets mapped to inv udc in the Zombieverter.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;#Can mapping to pass data and commands from the Zombieverter to the inverter is hard coded in the firmware for both devices.  Manual mapping is required for the inverter to transmit data to the Zombieverter.  The Zombieverter is hard coded to receive this data.  The following values need to be manually mapped in the inverter. Note: mapping uses hex address values, multipliers may need to change to provide correct values (confirm in Zombieverter spot values), inverter udc gets mapped to inv udc in the Zombieverter.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key wiki2-oo:diff:1.41:old-5553:rev-5574:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Steve16</name></author>
	</entry>
	<entry>
		<id>https://openinverter.org/wiki/index.php?title=Tesla_SDU_with_Zombieverter&amp;diff=5553&amp;oldid=prev</id>
		<title>Bratitude: Created page with &quot; ====Tesla SDU with Zombieverter==== 421x421pxNotes: *This drawing is intended to show the minimum components and connections needed for Zombieverter control of an OI SDU via Can bus.  Adapting power and Can bus connections for other OI inverters should function in the same manner, but this needs verification. *All power connections must be fuse protected.  Fuses are not shown...&quot;</title>
		<link rel="alternate" type="text/html" href="https://openinverter.org/wiki/index.php?title=Tesla_SDU_with_Zombieverter&amp;diff=5553&amp;oldid=prev"/>
		<updated>2025-01-31T23:39:14Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot; ====&lt;a href=&quot;/wiki/Tesla_SDU_with_Zombieverter&quot; title=&quot;Tesla SDU with Zombieverter&quot;&gt;Tesla SDU with Zombieverter&lt;/a&gt;==== &lt;a href=&quot;/wiki/File:Zombieverter_SDU_Wiring.png&quot; title=&quot;File:Zombieverter SDU Wiring.png&quot;&gt;alt=Zombieverter Can Bus Control of SDU |none|thumb|421x421px&lt;/a&gt;Notes: *This drawing is intended to show the minimum components and connections needed for Zombieverter control of an OI SDU via Can bus.  Adapting power and Can bus connections for other OI inverters should function in the same manner, but this needs verification. *All power connections must be fuse protected.  Fuses are not shown...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
====[[Tesla SDU with Zombieverter]]====&lt;br /&gt;
[[File:Zombieverter SDU Wiring.png|alt=Zombieverter Can Bus Control of SDU |none|thumb|421x421px]]Notes:&lt;br /&gt;
*This drawing is intended to show the minimum components and connections needed for Zombieverter control of an OI SDU via Can bus.  Adapting power and Can bus connections for other OI inverters should function in the same manner, but this needs verification.&lt;br /&gt;
*All power connections must be fuse protected.  Fuses are not shown for simplification.&lt;br /&gt;
*The following observations were made using Zombieverter firmware 2.20A and SDU firmware 5.35R:&lt;br /&gt;
#The Zombieverter does not enable inverter power prior to entering PreCharge mode.  An external device other than the inverter is required to supply the udc measurement for switch to Run mode.  This function is supported by the shunt and BMS options available in the Zombieverter parameters.&lt;br /&gt;
#A third device must be on the Can bus with the Zombieverter and Inverter.&lt;br /&gt;
#Requirements 1. and 2. are satisfied in the drawing by the IVT shunt.&lt;br /&gt;
#All devices except the Zombieverter are shown as powered by the ignition switch.  Some devices may need to move to permanent 12V supply to support other functions, such as charging.&lt;br /&gt;
#An inverter power relay is required for Zombieverter control.&lt;br /&gt;
#Can mapping to pass data and commands from the Zombieverter to the inverter is hard coded in the firmware for both devices.  Manual mapping is required for the inverter to transmit data to the Zombieverter.  The Zombieverter is hard coded to receive this data.  The following values need to be manually mapped in the inverter. Note: mapping uses hex address values, multipliers may need to change to provide correct values (confirm in Zombieverter spot values), inverter udc gets mapped to inv udc in the Zombieverter.&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;Spot Value&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;Hex Address&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;Offset&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;# Bits&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;Multiplier&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;Map&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|-&lt;br /&gt;
|speed&lt;br /&gt;
|400&lt;br /&gt;
|0&lt;br /&gt;
|16&lt;br /&gt;
|1&lt;br /&gt;
|Tx&lt;br /&gt;
|-&lt;br /&gt;
|tmphs&lt;br /&gt;
|410&lt;br /&gt;
|0&lt;br /&gt;
|16&lt;br /&gt;
|10&lt;br /&gt;
|Tx&lt;br /&gt;
|-&lt;br /&gt;
|udc&lt;br /&gt;
|420&lt;br /&gt;
|0&lt;br /&gt;
|16&lt;br /&gt;
|10&lt;br /&gt;
|Tx&lt;br /&gt;
|-&lt;br /&gt;
|opmode&lt;br /&gt;
|430&lt;br /&gt;
|0&lt;br /&gt;
|8&lt;br /&gt;
|1&lt;br /&gt;
|Tx&lt;br /&gt;
|}&lt;/div&gt;</summary>